OIL RESISTANCE TEST

1. Purpose
This procedure evaluates the physical and chemical properties of Anyang wires and cables to verify retention of critical mechanical properties—specifically tensile strength and elongation—following exposure to hydrocarbon-based fluids. Testing confirms compliance with Anyang Oil Resistance Cable Specifications, applicable industry standards, and safety agency requirements.

2. Methodology
Tubular or die-cut specimens are prepared to specified dimensions and fully immersed in the designated test fluid. The submerged samples are conditioned in a mechanical convection oven at elevated temperature for a prescribed duration.

Following the aging cycle, specimens are removed and stabilized at ambient conditions for a defined recovery period. Each sample is then mounted in a tensile testing apparatus and subjected to controlled elongation at a constant rate until fracture occurs.

3. Data Analysis
Post-exposure tensile strength and elongation values are electronically compared against standardized requirements through automated validation protocols, ensuring objective evaluation and measurement accuracy.

4. Compliance Standards

  • UL 62
  • UL 1581